EU118 KL3 Hybrid Solar Inverter 5-12KW

EU118 KL3 Hybrid Solar Inverter 5-12KW

Three phase hybrid inverter DC 48V | PV 550V

The EU118 KL3 series is a three-phase on/off-grid bidirectional energy storage inverter with a compact design and high power density. It supports lithium and lead-acid batteries, provides a stable 380V/400V three-phase output, and features remote monitoring and multiple safety protections. It is widely used in home energy storage, small commercial energy storage, smart microgrids, and off-grid power supply in remote areas.

Description

Product Description

■ 100% unbalanced output
■ Max. 6 pcs parallel for on-grid and off-grid operation
■ AC couple to retrofit existing solar system
■ Support multiple batteries parallel
■ Max. charging/discharging current of 320A
■ Support storing energy from diesel generator
■ 48V low voltage battery, transformer isolation design
■ IP66 water-proof and dust-proof
■ “Time of use” function: a maximum of 6 time segments can be set
■ Wifi monitoring

MODEL US118-5KL3 US118-6.5KL3 US118-8KL3 US118-10KL3 US118-12KL3 US118-13KL3 US118-14KL3 US118-15KL3 US118-16KL3
Rated power 5000W 6500W 8000W 10000W 12000W 13000W 14000W 15000W 16000W
BATTERY INPUT DATA
Battery type Lead-acid battery / Lithium battery
Battery voltage 48V
Battery voltage range 40~64V
Charging curve 4-stage adaptive with maintenance/Equalization
Charging Strategy for Li-lon Battery Self-adaption to BMS
Over-current protection/ Over-temperature protection Yes / Yes
Maximum charging/discharging power 5000W 6500W 8000W 10000W 12000W 13000W 14000W 15000W 16000W
Maximum charging/discharging current 120A 150A 190A 210A 240A 260A 280A 300A 320A
PV STRING INPUT DATA
Max. DC Input Power 6500W 8450W 10400W 13000W 15600W 16900W 18200W 19500W 20800W
Rated PV Input Voltage 550V 370V
Maximum DC voltage 800V 800V
Start-up Voltage 160V 125V
Minimum voltage for grid connection 200V 200V
Full Load DC Voltage Range 350-650V 352~650V 379~650V 406~650V 433~650V
Enter high voltage error recovery point 800V 800V
MPPT voltage range 200~650V 150~800V
Maximum input current 13A+13A 13A+26A 32A/16A 32A/16A 32A/16A 32A/16A
No.of MPP Trackers 2 3 3 3 3
No.of Strings per MPP Tracker 1+1 2+1 2+1
AC INPUT/OUTPUT DATA
Rated AC Input/ Output Power 5000W 6500W 8000W 10000W 12000W 13000W 14000W 15000W 16000W
Max AC Input/ Output Power 5500W 7150W 8800W 11000W 13200W 13000W 14000W 15000W 16000W
Rated AC Input/ Output Current 7.6A/7.2A 9.8A/9.42A 12.1A/11.6A 15.2A/14.5A 18.2A/17.4A 19.7A/18.8A 21.2A/20.3A 22.7A/21.7A 24.2A/23.2A
Max AC Input/ Output Current 8.4A/8A 10.8A/10.4A 13.4A/12.8A 16.7A/15.9A 20A/19.1A 20.6A/20.6A 22.6A/22.6A 23.8A/23.8A 25.5A/25.5A
Max. 3-Phase Unbalanced Current 11.4A/10.9A 14.7A/14.1A 18.2A/17.4A 22.7A/21.7A 27.3A/26.1A 29.5A/28.2A 31.8A/30.4A 34A/32.5A 36.3A/34.8A
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage 220/380,230/400Vac
Rated Input/Output Grid Frequency 60Hz±5Hz/50Hz±5Hz
Grid Type Three Phase
Total Harmonics Current Distortion (THDi) <3% (of nominal power)
DC Current Injection <0.5% In
EFFICIENCY
Max. Efficiency ≥97.6% ≥97.5%
Euro Efficiency 97.0% 96.5%
MPPT Efficiency 99.5%
PROTECTION
Integrated Islanding protection, Output overcurrent protection, Output overvoltage protection, DC switch rating for each MPPT, Grid monitoring, Output over current protection, Gird overvoltage protection-varistor,Integrated all-pole sensitive leakage current, ISO monitoring, over temperature protection.
Surge Protection AC Type III
Overvoltage Category AC Type III
GENERAL DATA
Operating Temperature Range (°C) -25°C~+60°C, >45°C Derating
Cooling Intelligent Fan
Noise (dB) ≤55dB
Communication with BMS RS485/CAN
Machine Dimension (W*H*D)(mm) 446*692*260 (excluding connectors and racks)
Package Dimension (W*H*D)(mm) 567*816*404
N.W(kg) 38 (Excluding Connectors and Brackets)
G.W(kg) 42
Protection Degree IP66
Installation Style Wall-mounted
Warranty 5 Year
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC 62109-1, EN IEC 62109-2); CE-LVD(EN 62477-1) ; IEC 60529; EN50549-1; Poland Type A, (NC RfG:2016,
PSE:2018, PTPiREE:2021)C10/C11; UNE217001-2020; UNE217002-2020, NTS-631 (Type A); G98+G99