PE200 Pure Sine Wave Inverter 300-1000W
Low Frequency Inverter DC 12/24V | AC 230V
PE200 series inverter is a cost effective, intelligent with UPS function. The comprehensive LCD offers user-configurable and easy-accessible button adjustment such as battery charge current, battery charge voltage, frequency, buzzer etc. It’s perfect for the user who need a simple and economical inverter,with user-friendly installnation and setting.Tower and rack design available for different choices.
Description
Product Description
■ Pure sine wave output
■ Smart LCD setting ( frequency , charge voltage,charge current, etc).
■ 3 steps charging algorithm
■ Built in AVR function
■ Overload and short-circuit protection
■ Battery reverse polarity protection (Optional)
■ Deep discharge protection
■ Cold start function
| MODEL | PE200-0312 | PE200-0412 | PE200-0512 | PE200-0612 | PE200-0812 | PE200-1012 | PE200-0624 | PE200-0824 | PE200-1024 |
| Default Battery System Voltage | 12VDC | 24VDC | |||||||
| INVERTER OUTPUT | |||||||||
| Rated Power | 300W | 400W | 500W | 600W | 800W | 1000W | 600W | 800W | 1000W |
| Surge Rating | 900VA | 1200VA | 1500VA | 1800VA | 2400VA | 3000VA | 1800VA | 2400VA | 3000VA |
| Waveform | Pure sine wave | ||||||||
| Voltage Regulation | Battery mode: 220 or 230VAC Line mode: 220~240VAC | ||||||||
| Output Frequency | 50Hz / 60Hz | ||||||||
| Invertert Frequency (Peak) | >75% | >81% | |||||||
| Bypass Efficiency | >95% | ||||||||
| Output Transfer Time | Typical:6ms 10ms(max) | ||||||||
| AC INPUT | |||||||||
| Voltage | 220 / 230 / 240VAC | ||||||||
| Selectable Voltage Range | 140~280VAC ±5% | ||||||||
| Low Battery Alarm | 140VAC ±5% | ||||||||
| Low Voltage Recover | 150VAC ±5% | ||||||||
| High Battery Alarm | 280VAC ±5% | ||||||||
| High Voltage Recover | 270VAC ±5% | ||||||||
| Low Frequency Alarm | 45 ±5Hz | ||||||||
| Low Frequency Recover | 46 ±5Hz | ||||||||
| High Frequency Alarm | 65 ±5Hz | ||||||||
| High Frequncy Recover | 64 ±5Hz | ||||||||
| Nominal Input Range | 50Hz / 60Hz ±5Hz | ||||||||
| AC Auto Restart | YES | ||||||||
| BATTERY | |||||||||
| Minimum Start Voltage | Low Battery Voltage Cutoff+0.5V | Low Battery Voltage Cutoff+0.5V | |||||||
| Low Battery Alarm | Low Battery Voltage Cutoff+0.5V | Low Battery Voltage Cutoff+1.0V | |||||||
| Min battery voltage for power on | Shutdown voltage +0.5V | Shutdown voltage +1V | |||||||
| Low Battery Cutoff | 10-12.0VDC | 20.0-24.0VDC | |||||||
| High Battery Alarm | (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC) | ||||||||
| AC CHARGE | |||||||||
| Floating Voltage | 13.5-14.5VDC | 27-29VDC | |||||||
| Boost Voltage | 13.8~14.5V | 27.6~29V | |||||||
| Maximum Charge Current | 300W | 400W | 500W | 600W | 800W | 1000W | 600W | 800W | 1000W |
| 10A | 10A | 15A | 20A | 25A | 30A | 10A | 15A | 15A | |
| BYPASS & PROTECTION | |||||||||
| Input Waveform | Pure sine wave | ||||||||
| Input Frequency | 50Hz or 60Hz | ||||||||
| Overload Protection | >110%~125% Load foult affter 60s; >125%~150% Load foult affter 3s; >150% Load fault after 500ms | ||||||||
| Over Temperature Protection | ≥90℃ | ||||||||
| Bypass Output Protection | 10A 250VAC | ||||||||
| Output Circuit Protection | YES | ||||||||
| Battery Reverse Protection | Optional | ||||||||
| Battery Low Voltage Protection | YES | ||||||||
| Battery High Voltage Protection | YES | ||||||||
| Bypass Breaker Rating | 10A | ||||||||
| Maximum Bypass Current | 10A | ||||||||
| MECHANICAL SPECIFICATION | |||||||||
| Machine Dimension (W*H*D) | 300.5*319*132.2mm | ||||||||
| Operating Temperature | 0℃ ~40℃ 0~90% relative humidity (non-condensing) | ||||||||
| Storage Temperature | -15℃ to 55℃ | ||||||||
| Altitude | ≤1000M | ||||||||
| Audible Noise | ≤60dB | ||||||||
| Display | LED+LCD | ||||||||
| Cooling Mode | Fan cooling | ||||||||
| Fan Starting | >45℃ starting, <30℃ Closing | ||||||||
| Communication | USB | ||||||||